Description:
Thin wall heat-shrink tubing in cross-linked polyolefin with high mechanical strength and chemical resistance.
Shrink ratio: 3:1
Materials: Crosslinked EVA
Installation temperature:
- Shrinking temperature: > 90°C
- Operating temperature: -55°C to +105°C
Application:
- Public transport
- Panel building
- Industrial installations
- Aerospace, defense
Features and benefits
- Halogen free
- Very good fluid resistance
- Weather & UV resistant
- Very flexible, smooth surface, excellent printability
- Highest safety class in rail transport: low smoke and toxicity emissions
- Permanent identification result
Download:
Standard packaging:
Reel
Related products:
FLZH301B,
Y501P,
Y501P-DR
Tags

| DIMENSIONS | ||||||
|---|---|---|---|---|---|---|
| Size | Min. Ø supplied "D" [mm] | Max. Ø recovered "d" [mm] | Min.-Max. recovered wall thickness "W" [mm] | Min.-Max. supplied wall thickness "w" [mm] | Concentricity expanded [%] | |
| [inch] | [mm] | |||||
| 3/32 | 2,4 | 2,4 | 0,8 | 0,43-0,63 | 0,15-0,25 | 65 |
| 1/8 | 3,2 | 3,2 | 1,2 | 0,43-0,68 | 0,15-0,25 | 65 |
| 3/16 | 4,8 | 4,8 | 1,6 | 0,43-0,68 | 0,15-0,25 | 65 |
| 1/4 | 6,4 | 6,4 | 2,4 | 0,56-0,71 | 0,20-0,42 | 65 |
| 3/8 | 9,5 | 9,5 | 3,2 | 0,56-0,71 | 0,20-0,42 | 65 |
| 1/2 | 12,7 | 12,7 | 4,7 | 0,56-0,80 | 0,20-0,45 | 65 |
| 3/4 | 19,1 | 19,1 | 6,4 | 0,80-1,00 | 0,25-0,50 | 65 |
| 1 | 25,4 | 25,4 | 8,5 | 0,81-1,15 | 0,28-0,53 | 65 |
| 1 1/2 | 38,1 | 38,1 | 13,5 | 0,90-1,25 | 0,32-0,57 | 65 |
Physical properties:
| Description | Test method | Requirements | Test results |
|---|---|---|---|
| Dimensional | EN IEC 60684-2 | in-house | pass |
| Dimensional stability on storage | in-house | pass | |
| Tensile strength | min. 7MPa | 11MPa | |
| Elongation at break | min. 200% | 230% | |
| Secant modulus at 2% | 40-130MPa | 121MPa | |
| Longitudinal change | -10 to +5% | pass | |
| Water absorption | max. 1% | 0,5% | |
| Density | - | 1,40 |
Thermal properties:
| Description | Test method | Requirements | Test results |
|---|---|---|---|
| Heat shock 4h at 150°C | EN IEC 60684-2 | no drip, crack, flow | pass |
| - Tensile strength | min. 6MPa | 13MPa | |
| - Elongation at break | min. 100% | 225% | |
| Heat ageing 168h at 135°C | - | - | |
| - Tensile strength | min. 5MPa | 12MPa | |
| - Elongation at break | min. 150% | 210% | |
| Bending at low temp. -55°C | no cracking shall be visible | pass |
Chemical properties:
| Description | Test method | Requirements | Test results |
|---|---|---|---|
| Resistance to selected fluids | EN IEC 60684-2 | EN IEC 60684-3-216 tab. 7 | pass Tested fluids: ISO1817 liq. B, F, 101, 103 and oil no. 2; S-1714; H-520; O-1176; O-142; Cleaning fluids; Runway de-icers; Aircraft de-icers |
| - Tensile strength | min. 4MPa | ||
| - Elongation at break | min. 100% | ||
| Copper mirror corrosion | no corrosion of mirrors | pass | |
| Colour fastness to light | fastness standard 5 | pass | |
| Acid gas generation | EN IEC 60754-2 |
3,5-10,5 |
pass |
Fire properties:
| Description | Test method | Requirements | Test results |
|---|---|---|---|
| - Horizontal flammability | ASTM D635 |
burning rate ≤40mm/min. |
class HB |
| - Vertical flammability / flame propagation | EN IEC 60684-2 met. A1) | time of burning ≤60s; the indicator flag shall not be damaged more than 25 %; no ignition of the cotton |
≥1" |
| Fire protection on railway EN 45545-2 | R22\R23\R24 | pass for hazard level HL1, HL2 and HL3 | |
| - Oxygen index [OI] | EN ISO 4589-2 | ||
| - Smoke density Ds | EN ISO 5659-2 | ||
| - Toxicity | EN 17084 | ||
| Toxic gas generation | BSS 7239 | defined by the method | pass |
Physicochemical properties:
| Description | Test method | Requirements | Test results |
|---|---|---|---|
| UV resistance | ASTM G154 | min. 50% of non-aged physical properties | pass |
| - Tensile strength | |||
| - Elongation at break |
Electrical properties:
| Description | Test method | Requirements | Test results |
|---|---|---|---|
| Breakdown voltage | EN IEC 60684-2 | min. 7kV | 22kV |
| Volume resistivity at room temp. | min. 1010Ωm | 3,7*1010Ωm | |
| Volume resistivity after damp heat conditions | min. 109Ωm | 7,1*1010Ωm |
Note: Unless otherwise stated, all values are determined in accordance with EN IEC 60684-2. The measured characteristics correspond to properties commonly evaluated under ASTM D2671.
1) The applied testing procedure is largely consistent with the UL224 pt. 5.11 Flame test - all tubing, ASTM D2671-13 procedure B and ASTM D267121 method C. The products are tested in their shrunk form i.e., as they are intended to be applied on final application.
Approval:
- EN 45545-2 requirements R22\R23\R24, class HL1, HL2 and HL3
- Boeing BSS 7239
- MIL-STD-202 met. 215
- SAE AS5942
- Complies with REACH and RoHS