Sunday, November 29, 2026

Search

Language

Baner EN

OUR DAILY WORK
...not word should proof our quality
but our day to day work!

Professional equipment, in-line monitoring and frequent measurements & control by dedicated, skilled people guarantees a constant high quality output of production.

PRODUCT IDENTIFICATION
We want to keep it really
easy to You!

The ECS Cable Protection's product identification offer is based on excellent printable heat shrink tubing. It includes cable & wire identification, customized marking and print job service.

Brochure

CUSTOMER SATISFACTION
...our target!

As long as the company exists we have been focusing on customer needs. Our products, quality, packaging, flexibility, service, reliability, communication and action is in line with this principle!

FAST AND FLEXIBLE
...to find always the best solution for You!

A dynamic, enthusiastic, skilled and professional team of people is focused and creative to find the best solution. In time this has lead to many strong business relationships.

CUSTOMIZED PRODUCTS
We go further in customizing
where other stop!

Customized packaging, sizing and marking differentiate your products from competition. We can and want to help you!

Read more...

A- A A+

NF301P

  • Basic inf.

  • Sizes

  • Colors (5)

  • Properties

  • Certification

  • Approval

NF301P

Description:

Flexible, self-extinguishing thin-wall heat-shrink polyolefin tubing, UL/CSA recognized High shrink ratio designed and sized to be flattened for identification purposes.

Shrink ratio: 3:1

Materials: Crosslinked EVA
Installation temperature:

  1. Shrinking temperature:  > 90°C
  2. Operating temperature: -55°C to +135°C

Features and benefits

  1. UL Recognized Component (US & Canada)
  2. 3:1 ratio - fits parts 3x larger than the cable
  3. Wide range of sizes
  4. Fast installation with heat guns
  5. Wide temperature window
  6. Self-extinguishing
  7. Remains flexible after recovery
  8. 600V insulation rating

Download:

pdf NF301P |  Supplementary safety information

Standard packaging:
article icon Reel

Related products:
article icon FLNF301P, article icon NS201, article icon NF201, article icon NF301, article icon HAG, article icon CHAG

Tags help icon 

 tube

DIMENSIONS
SizeMin. Ø supplied "D" [mm] Max. Ø recovered "d" [mm] Min-max. recovered wall thickness "W"
[mm]
Min max. supplied wall thickness "w"
[mm]
Min, concentricity expanded
[%]
[inch][mm]
3/32 2,4 2,4 0,8 0,43-0,63 0,15-0,25 50
1/8 3,2 3,2 1,0 0,43-0,68 0,15-0,25 50
3/16 4,8 4,8 1,6 0,43-0,68 0,15-0,25 50
1/4 6,4 6,4 2,0 0,56-0,71 0,20-0,42 50
3/8 9,5 9,5 3,0 0,56-0,71 0,20-0,42 50
1/2 12,7 12,7 4,0 0,56-0,80 0,20-0,45 50
3/4 19,1 19,1 6,0 0,80-1,00 0,25-0,50 50
1 25,4 25,4 8,0 0,81-1,15 0,28-0,53 50
1 1/2 38,1 38,1 12,7 0,90-1,25 0,32-0,57 50

Standard colors *:

  • WHITE

  • YELLOW

Non-standard colors *:

  • BLACK

  • RED

  • BLUE

*Listed above colours are illustrative and can differ from the physical samples. The differences arise because of differences in hardware monitors, printers and other devices.

Physical properties:

DescriptionTest methodRequirementsTest results
Dimensional EN IEC 60684-2 in-house pass
Tensile strength min. 10,3MPa 11,4MPa
Elongation at break min. 200% 480%
Secant modulus at 2% max. 173MPa 103MPa
Longitudinal change -10 to +5% pass
Restricted shrinkage no cracking or splitting pass
Water absorption max. 1% 0,5%
Density - 1,30

Thermal properties:

DescriptionTest methodRequirementsTest results
Heat shock 4h at 250°C EN IEC 60684-2 - -
- Visual no signs of dripping and cracking pass
- Flow max. 10%
- Visual after bending no cracking when cooled and wound 360° around a mandrel
Heat ageing 168h at 160°C -  -
- Tensile strength min. 7,3MPa 12,2MPa
- Elongation at break min. 100% 512%
- Breakdown voltage min. 2,5kV and not less than 50% breakdown of the un-aged sleeving pass: 32kV
Bending at low temp. -55°C no cracking shall be visible pass

Chemical properties:

DescriptionTest methodRequirementsTest results
Resistance to selected fluids EN IEC 60684-2 min. 50% of non-immersed physical properties

pass T

ested fluids: ISO1817 oil no. 2; Sodium hydroxide; Hydrochloric acid; Diesel; Hydraulic oil

- Tensile strength
- Elongation at break

Fire properties:

DescriptionTest methodRequirementsTest results
Vertical flammability - flame test  UL224 pt. 5.11

time of burning ≤60s; the indicator flag shall not be damaged more than 25%; no ignition of the cotton

pass
Fire protection on railway EN 45545-2
- Oxygen index [OI] EN ISO 4589-2 R22\R23\R24 pass R22 - HL1 R23/R24 - HL2
- Smoke density Ds EN ISO 5659-2
- Toxicity EN 17084
Fixed Guideway Transit and Passenger Rail Systems NFPA 130
- Surface flammability [ls] ASTM E162 ls≤35;  no flaming running or dripping pass
- Smoke optical density Ds ASTM E662 Ds1,5≤100; Ds4,0≤200; pass
Burning behaviour of motor vehicles ECE no. 118.03
- Vertical flammability ECE no. 118.03 ann. 8 V≤100 mm/min. pass

Physicochemical properties:

DescriptionTest methodRequirementsTest results
1000 h UV resistance, (8 h UV / 4 h condensation) ASTM G154 min. 50% of non-aged physical properties pass
- Tensile strength
- Elongation at break
Fungus resistance ASTM G21 - -
- Tensile strength min. 10,3MPA 11,4MPa
- Elongation at break min. 200% 500%

Electrical properties:

DescriptionTest methodRequirementsTest results
Breakdown voltage EN IEC 60684-2 min. 2,5kV 21kV
Volume resistivity at room temp. min. 1012Ωm 2,3*1012Ωm
Dielectric constant ASTM D150 max. 3,1 2,8
Voltage rating UL224 600V 600V

Note: Unless otherwise stated, all values are determined in accordance with EN IEC 60684-2. The measured characteristics correspond to properties commonly evaluated under ASTM D2671.


Certification:
UL224 / CSA C22.2 No. 198.1 File E228117, 125°C, 600V 1)

1) Recovered ID up to 12.7 mm. 

Approval:

  1. Tested acc. to SAE AS23053/5 2)
  2. EN 45545-2
  3. NFPA130
  4. ECE no. 118.03
  5. Complies with REACH and RoHS

2) Meets all requirements of SAE AS23053/5 class 4, except fluid resistance in JP-8 (MIL-DTL-83133) and petroleum-based hydraulic fluid (MIL-PRF-5606).. 