Description:
Highly flame retardant, semi rigid,fluor polymer heat shrink tubing suitable for applications with extreme temperatures, chemical or electrical requirements.
Features:
- Applicable in extreme chemical and thermal environments
- High shrink ratio
- Transparent
- Semi rigid
- Minimum shrink temperature > 330°C
- Operating temperature -200°C to +260°C
Download:
Standard packaging:
Meter lengths,
Reels

Size [inch] | Minimum Inside Diameter Supplied [mm] | Maximum Inside Diameter Recovered [mm] | Wall Thickness Recovered [mm] |
---|---|---|---|
5/64 | 1,98 | 0,64 | 0,17 - 0,27 |
1/8 | 3,18 | 0,94 | 0,20 - 0,30 |
3/16 | 4,75 | 1,27 | 0,22 - 0,38 |
1/4 | 6,35 | 1,60 | 0,22 - 0,38 |
5/16 | 7,92 | 2,00 | 0,22 - 0,38 |
3/8 | 9,52 | 2,44 | 0,22 - 0,38 |
7/16 | 11,13 | 2,85 | 0,22 - 0,38 |
1/2 | 12,70 | 3,66 | 0,22 - 0,38 |
9/16 | 14,27 | 3,94 | 0,28 - 0,48 |
5/8 | 15,88 | 4,52 | 0,28 - 0,48 |
11/16 | 17,45 | 5,03 | 0,28 - 0,48 |
3/4 | 19,05 | 5,70 | 0,28 - 0,48 |
7/8 | 22,23 | 6,20 | 0,28 - 0,48 |
1 | 25,40 | 7,06 | 0,28 - 0,48 |
1 1/4 | 31,75 | 8,82 | 0,28 - 0,48 |
1 1/2 | 38,10 | 10,20 | 0,28 - 0,48 |
1 3/4 | 44,45 | 11,43 | 0,28 - 0,48 |
2 | 50,80 | 13,20 | 0,37 - 0,63 |
2 1/4 | 57,15 | 14,85 | 0,37 - 0,63 |
Property | Test method | Typical value |
---|---|---|
Tear strength at 230C | ISO 527 | 29-39 N/mm2 |
Yield strength at 230C | ISO 527 | 10 N/mm2 |
Tensile E-Modulus at 230C | ISO 527 | 400-800 N/mm2 |
Bending E-Modulus | ISO 527 | 600-800 N/mm2 |
Elongation at break at 230C | ISO 527 | 200-500% |
Longitudinal change | - | -10% to +10% |
Water absorption | - | <0,05% |
Specific gravity | ISO 1183 | 2,14-2,19 |
Shore hardness | DIN 53505 | D 55-72 |
Property | Test method | Typical value |
---|---|---|
Melting temperature | ASTM 2116 | 3270C |
Upper service temperature | - | 250-2600C |
Lower service temperature | - | -2000C |
Flammability | UL94-V0 | pass |
Property | Test method | Typical value |
---|---|---|
Dielectric constant at 100Hz | IEC 60250 | < 2,1 |
Dielectric loss factor at 100Hz | - | 0,5-0,7*10-4 |
Dielectric strength | IEC 60243-2 | >40 kV/mm |
Specific flow resistance | IEC 60093 | >1016 Ohm |